Rapid Exhaust Valve Series
One-touch fitting built-in rapid exhaust valve
It is compatible with high-speed drive of the cylinder. It can also be used as a shuttle valve.
- Company:日本ピスコ
- Price:Other
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.
1~9 item / All 9 items
One-touch fitting built-in rapid exhaust valve
It is compatible with high-speed drive of the cylinder. It can also be used as a shuttle valve.
Options for check valves that can be used for filling and discharging in satellite propulsion systems have been released! They can be used as intake and exhaust valves!
- Uses Lee products' check valves, which have a rich track record in space from the Apollo program to the present. - Compact and lightweight. - Redundant sealing function. - Fitting structure made of stainless steel or titanium. - Seal options of Metal to Metal, elastomer, or polymer. - Compatible with all types of storable gases and propellants. - Adjustable to fit mounting interfaces and tube sizes. - Forms an extremely strong seal with fitting caps and gaskets, with a leak rate of less than 1.0 x 10^-7 SCCS. - Fully customizable to suit applications. Separate pilot tool for weight reduction. - Weighs only 38 grams (55 grams with cap and gasket attached). - With cap and gasket attached, helium leakage is less than 10^-7 SCC at 4000 psid. - Various materials are available for fluid compatibility. - Custom interfaces are available. - Built to aerospace quality standards AS9100.
Introduction to the important "residual pressure exhaust" for ensuring operator safety and efficient maintenance.
This document introduces the important topic of "residual pressure exhaust" for ensuring worker safety and efficient maintenance, along with examples. Residual pressure poses risks such as parts being blown off, workers tripping, and hazardous materials being ejected. To ensure worker safety, it is crucial not only to stop the pressure supply but also to thoroughly exhaust residual pressure. [Contents] ■ Unexpected accidents that can occur due to residual pressure ■ Residual pressure exhaust valves that help prevent accidents ■ Even when machines are stopped, do not let your guard down; ensure residual pressure exhaust ■ Reference sites *For more details, please refer to the PDF document or feel free to contact us.
Produced since 1968! Proposed as railway use based on commercial vehicle performance.
The "Rapid Exhaust Valve" is mass-produced for commercial vehicles and is a low-cost product. It is used for rapid air exhaust in air actuators and similar applications. The operating temperature range is -30 to 70°C, with a durability of 1 million cycles. It also has a proven track record for air brake applications, ensuring high reliability. 【Features】 ■ Mass-produced for commercial vehicles ■ Low cost ■ Proven track record for air brake applications ■ High reliability *For more details, please refer to the PDF document or feel free to contact us.
Space-saving and reduction of piping labor is possible! You can select with a soft startup function.
The "VP346E/546E/746E/946E series" is a modular type 3-port residual pressure exhaust valve. It can be connected to the F.R.L. combination "AC-D series." The power consumption is 0.35W (without lamp). Additionally, a check valve is built into the pilot flow path, which responds to pilot pressure drops caused by pressure fluctuations on the primary side. 【Features】 ■ Can be connected to the F.R.L. combination "AC-D series" ■ Space-saving and reduction of piping work is possible ■ Selection with soft startup function is available ■ Power consumption: 0.35W (without lamp) ■ Check valve built into the pilot flow path (responds to pilot pressure drops due to pressure fluctuations on the primary side) *For more details, please download the PDF or feel free to contact us.
New simple exhaust valve with diagnostic function. Perfect as a replacement air valve too!
The "Shinemon C200 Series" is an exhaust valve with operational confirmation that was developed based on feedback from water supply organizations nationwide. In some installation sites, a small amount of exhaust is sufficient, and there was a demand for an air valve that is lower in price than rapid air valves, yet allows for operational confirmation, pipe cleaning, and easy maintenance. This product was developed in response to that request. By turning the butterfly screw or bolt (operational check valve) located on the side of the main body one full rotation while the auxiliary valve is open, you can confirm whether the air valve is functioning properly. For more details, please contact us or refer to the catalog.
We respond to our customers' needs with high trust and technical expertise.
Our company primarily manufactures diesel engine parts. In particular, the exhaust valves incorporated in exhaust valve-equipped products are manufactured and sold as high-quality products that can withstand harsh conditions in terms of wear resistance, impact resistance, and heat resistance. We also perform welding processing of various parts using plasma arc welding and TIG automatic welding, as well as heat treatment operations such as carburizing, quenching, and tempering. We are committed to providing higher quality products, so please feel free to consult with us. 【Business Activities】 ■ Manufacturing and sales of internal combustion engine parts ■ Manufacturing and sales of industrial machine parts ■ Repair and maintenance of land and marine engine parts ■ General heat treatment (quenching, tempering, hardening, annealing, carburizing) ■ Various welding and joining *For more details, please feel free to contact us.
Install in the middle of the piping between the leak tester and the work to exhaust air when the leak test is completed.
Prevents foreign matter such as water, oil, and dust in the works and piping from entering the leak tester, thereby preventing malfunctions and quality deterioration. We recommend especially when performing both water dunk and air leak tests. It can be used at test pressures of up to 4.9 MPa.